The geometrical accuracy of a custom artificial intervertebral disc implant manufactured using Computed Tomography and Direct Metal Laser Sintering

Show simple item record

dc.contributor.author De Beer, N.
dc.contributor.author Odendaal, A.I.
dc.contributor.other Central University of Technology, Free State, Bloemfontein
dc.date.accessioned 2015-10-02T10:39:21Z
dc.date.available 2015-10-02T10:39:21Z
dc.date.issued 2012
dc.date.issued 2012
dc.identifier.issn 16844998
dc.identifier.uri http://hdl.handle.net/11462/613
dc.description Published Article en_US
dc.description.abstract Rapid Manufacturing (RM) has emerged over the past few years as a potential technology to successfully produce patient-specific implants for maxilla/facial and cranial reconstructive surgeries. However, in the area of spinal implants, customization has not yet come to the forefront and with growing capabilities in both software and manufacturing technologies, these opportunities need to be investigated and developed wherever possible. The possibility of using Computed Tomography (CT) and Rapid Manufacturing (RM) technologies to design and manufacture a customized, patient-specific intervertebral implant, is investigated. Customized implants could aid in the efforts to reduce the risk of implant subsidence, which is a concern with existing standard implants. This article investigates how accurately the geometry of a customized artificial intervertebral disc (CAID) can represent the inverse geometry of a patient's vertebral endplates. The results indicate that the endplates of a customized disc implant can be manufactured to a calculated average error of 0.01mm within a confidence interval of 0.022mm, with 95% confidence, when using Direct Metal Laser Sintering. en_US
dc.format.extent 331 541 bytes, 1 file
dc.format.mimetype Application/PDF
dc.language.iso en_US en_US
dc.publisher Journal for New Generation Sciences, Vol 10, Issue 3: Central University of Technology, Free State, Bloemfontein
dc.relation.ispartofseries Journal for New Generation Sciences;Vol 10, Issue 3
dc.subject Rapid Manufacturing en_US
dc.subject Direct Metal Laser Sintering en_US
dc.subject Total disc replacement en_US
dc.subject Artificial disc en_US
dc.subject Computed Tomography en_US
dc.title The geometrical accuracy of a custom artificial intervertebral disc implant manufactured using Computed Tomography and Direct Metal Laser Sintering en_US
dc.type Article en_US
dc.rights.holder Central University of Technology, Free State, Bloemfontein