Abstract:
Rapid Manufacturing (RM) has emerged over the past few years as a potential technology to successfully produce patient-specific implants for maxilla/facial and cranial reconstructive surgeries. However, in the area of spinal implants, customization has not yet come to the forefront and with growing capabilities in both software and manufacturing technologies, these opportunities need to be investigated and developed wherever possible.
The possibility of using Computed Tomography (CT) and Rapid Manufacturing (RM) technologies to design and manufacture a customized, patient-specific intervertebral implant, is investigated. Customized implants could aid in the efforts to reduce the risk of implant subsidence, which is a concern with existing standard implants. This article investigates how accurately the geometry of a customized artificial intervertebral disc (CAID) can represent the inverse geometry of a patient's vertebral endplates. The results indicate that the endplates of a customized disc implant can be manufactured to a calculated average error of 0.01mm within a confidence interval of 0.022mm, with 95% confidence, when using Direct Metal Laser Sintering.