DSpace Repository

Investigating the effective removal of fat, oil and grease (FOG) in water treatment plants of the Mangaung Metropolitan Municipality

Show simple item record

dc.contributor.advisor Oke, S
dc.contributor.author Sello, Mpho Gladness
dc.date.accessioned 2024-08-29T04:12:08Z
dc.date.available 2024-08-29T04:12:08Z
dc.date.issued 2023
dc.identifier.uri http://hdl.handle.net/11462/2582
dc.description Thesis (Master: Engineering: Civil Engineering)--Central University of Technology en_US
dc.description.abstract The most common type of wastewater under low-strength waste streams is municipal wastewater. It is characterised by low organic strength and high particulate organic matter constituents. Common pollutants in municipal wastewater include viruses, bacteria, protozoa, helminths, suspended solids, total dissolved solids, a few chemicals, nitrates, phosphates and fats, oil and grease (FOG). The presence of high concentrations of nitrates and phosphates in wastewater effluent can cause eutrophication of receiving water bodies. On the other hand, FOG in the wastewater treatment plants leads to inefficiencies of the wastewater system, resulting in severe environmental degradation and contamination of water resources. As a result, optimal wastewater treatment technology is one of the most used criteria for the treatment of wastewater. The activated sludge and trickling filter systems are both known to remove FOG; however, the degree of efficiency of each method against the other in the removal of FOG is not known. The effectiveness and degree of the activated sludge compared to the biological trickling filter system in the removal of FOG showed no difference, since both treatment plants release FOG in their effluents. This study presented findings from investigating the effectiveness of the wastewater treatment technologies in two treatment plants in the Mangaung Metropolitan Municipality (MMM) in South Africa. The study was conducted to compare the efficiency of the trickling filter and activated sludge systems in the treatment of FOG, nitrogen and phosphorus and the possible correlation of nitrates and phosphates to FOG. The effects of other parameters such as pH, atmospheric pressure, temperature, dissolved oxygen, salinity, conductivity, resistivity and total dissolved solids were also investigated. Twenty grab samples of both the influent and effluent of the NEWTP and the BWTP were collected in total for the months; June, July, August, September and October. Samples were analysed at the laboratory of the MMM situated at the BWTW. The sampling and laboratory analysis of FOG followed the description of the Environmental Protection Agency (EPA 1664B). The hexane extraction and gravimetric method was used in the analysis. Nitrates were sampled and analysed using a SOP Chem 005 Spectroquant nitrate test, while phosphates were sampled and analysed using a Spectroquant Prove spectrophotometer in the laboratory. The Hanna HI98192 and Hanna HI98193 multimeters were used for field measurements of pH, dissolved oxygen, temperature, atmospheric pressure, conductivity, resistivity, salinity and total dissolved solids. The results showed that the trickling filter system from BWTP removed FOG by 61.36%, while the activated sludge system from NEWTP removed FOG by 52.81%, which showed that the trickling filter system is more effective than the activated sludge system in the removal of FOG. On the other hand, the removal of nitrates and phosphates was found to be within the effluent discharge standards. The regression analysis for both BWTW and NEWTP showed a strong correlation between nitrates and FOG. In addition, the regression analysis for phosphates and FOG in both wastewater treatment plants also indicated a strong correlation between the two variables. Furthermore, the removal of nitrates and phosphates was found to be satisfactory and complying with the South African discharge standards. Similarly, phosphate levels in the effluents of the two plants were also found to be complying with the South African effluent discharge standards. This concluded that the volume of FOG found in the effluents of these plants was influenced by the volume of nitrates and FOG. In addition, the comparison of the trickling filter and activated sludge systems indicated that the trickling filter system is an efficient treatment method for the treatment of FOG, compared to the activated sludge system. en_US
dc.publisher Central University of Technology en_US
dc.subject Activated sludge en_US
dc.subject FOG en_US
dc.subject Nitrates en_US
dc.subject Phosphates en_US
dc.subject Trickling filter en_US
dc.subject Wastewater treatment en_US
dc.title Investigating the effective removal of fat, oil and grease (FOG) in water treatment plants of the Mangaung Metropolitan Municipality en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account