DSpace Repository

Optimisation of recloser placement methods on medium voltage distribution networks

Show simple item record

dc.contributor.advisor Hertzog, PE
dc.contributor.author Strydom, Renaldo
dc.date.accessioned 2024-08-20T06:36:40Z
dc.date.available 2024-08-20T06:36:40Z
dc.date.issued 2022
dc.identifier.uri http://hdl.handle.net/11462/2572
dc.description Thesis (Master: Engineering: Electrical)--Central University of Technology en_US
dc.description.abstract Re-evaluating methods in any business is essential, as it reinforces knowledge and improves methodologies. Improving the reliability of electrical distribution networks is key for a utility like Eskom. Having fewer customers without electricity during an outage and more income for the utility is the focus of this study. Eskom’s standard for placing reclosers (automatic breakers) focuses on reaching their performance targets and not on the financial costs and benefits thereof. The purpose of this study is to present a method to optimise the placement of reclosers on the distribution networks. Eskom could, by focusing on the financial benefits of recloser placement, improve their performance targets as well as save more money on fault conditions. A method using cost-benefit analysis (CBA) is used and explained to analyse the placement of reclosers on an electrical distribution network. Mathematical calculations and a matrix table are used to determine the maximum number and sequence of placement of the reclosers to be installed on the networks. The findings of this study show that placing reclosers on the network using this method will pay for itself in a short period. The results show the financial benefits as well as performance improvements. By using the proposed method, the exact placements for reclosers may be indicated and less guesswork will be required from the engineers. The study was done using data from actual distribution networks. Possible future studies can be done by combining recloser placements with other protection-sensing equipment such as Fault Path Indicators or Current Voltage Monitors. en_US
dc.publisher Central University of Technology en_US
dc.subject Electrical distribution networks en_US
dc.subject Reclosers (automatic breakers) en_US
dc.subject Recloser placement en_US
dc.subject Cost-benefit analysis (CBA) en_US
dc.title Optimisation of recloser placement methods on medium voltage distribution networks en_US
dc.type Thesis en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account