DSpace Repository

Intradialytic hypertension during chronic haemodialysis and subclinical fluid overload assessed by bioimpedance spectroscopy

Show simple item record

dc.contributor.author Sebastian, Sajith
dc.contributor.author Filmalter, Christelle
dc.contributor.author Harvey, Justin
dc.contributor.author Chothia, Mogamat-Yazied
dc.date.accessioned 2019-01-23T06:56:39Z
dc.date.available 2019-01-23T06:56:39Z
dc.date.issued 2016
dc.identifier.uri http://hdl.handle.net/11462/1874
dc.description Published Article en_US
dc.description.abstract Background: Intradialytic hypertension (IDH) increases morbidity and mortality. The prevalence in South Africa is unknown. The pathogenesis is unclear, but it has been suggested that IDH may be due to subclinical fluid overload. The objective of this study was to determine the prevalence of IDH and to evaluate its association with fluid overload using bioimpedance spectroscopy (BIS). Methods: A cross-sectional study involving 190 chronic haemodialysis patients in the Western Cape province of South Africa was conducted between January 2013 and May 2014. IDH was defined as a >10 mmHg increase in systolic blood pressure in at least four of six prior consecutive haemodialysis sessions. Results: The prevalence of IDH was 28.4% (n = 54). Therewas a trend towards pre-dialysis overhydration in the IDH group when compared with controls {2.6 L [95% confidence interval (CI) 1.7–3.4] versus 1.8 L [95% CI 1.4–2.1], respectively; P = 0.06} as measured by BIS, but no difference in mean ultrafiltration (UF) volume (2.4 versus 2.6 L; P = 0.30). A trend towards greater use of antihypertensive drugs was noted in the IDH group [2.5 drugs (95% CI 2.15–2.87) versus 2.1 (95% CI 1.82–2.30); P = 0.05]. More participants in the IDH group received calcium channel blockers (54 versus 36; P = 0.03). Conclusions: The prevalence of IDH in our treatment centres is much higher than previously reported. Subclinical fluid overload may be a major contributing factor to the mechanism of this condition. The use of BIS identifies patients who may benefit from additional UF. en_US
dc.format.extent 571 965 bytes, 1 file
dc.format.mimetype Application/PDF
dc.language.iso en_US en_US
dc.publisher Clinical Kidney Journal en_US
dc.relation.ispartofseries vol. 9;no. 4
dc.subject bioimpedance monitoring en_US
dc.subject haemodialysis en_US
dc.subject intradialytic hypertension en_US
dc.title Intradialytic hypertension during chronic haemodialysis and subclinical fluid overload assessed by bioimpedance spectroscopy en_US
dc.type Article en_US